11 product ratings. The heated diode’s advantage is that it detects absolute concentration levels so it can be held on a leak and will continue to beep. The main disadvantage of infrared sensors is their sensitivity to mechanical disturbances. The sensor is connected to the body at the other end of the snout. This may just be me but one of the biggest selling points of this product is the The SRL8 Heated Diode Refrigerant Leak Detector is designed exclusively to make the HVAC/R Technician’s job easier, faster, safer and more efficient. Listing claimed it was brand new and it did look brand new, zero scratches or scuffs or signs of wear on anything, rubber looked and felt brand new. The Fieldpiece SRL8 is an ergonomic ruggedly built refrigerant leak detector that uses a heated diode sensor to detect all CFCs, HFCs, and HCFCs refrigerants consistently and accurately. Related Manuals for Fieldpiece SRL8 . Would recommend. The Fieldpiece RHD1 is a replacement sensor for the SRL8 Refrigerant Leak Detector. The sensor can be inserted in two different configurations, either of which will allow the SRL8 to function correctly. FAQs, SRL8 - Heated Diode Refrigerant Leak Detector, SRL8 - Kältemittel-Lecksuchgerät mit beheizter Diode, SRL8 Detector de fugas de refrigerante con diodo calient, SRL8 - Détecteur de fuite d'agent frigorigène à diode chauffée, SRL8 Modelo de Detetor de Vazamentos de Fluído Refrigerante com Sensor Diodo Aquecido. Model RFL2contains 10 filters and 5 O-rings. Mute: Turn off the sound when you don’t want anyone to hear what you’re doing. and the LED bar graph will light up. Sometimes we’re in a hurry and we forget a critical component on a job, or a fuse blows, or batteries die. 3. 15-hour rechargeable lithium ion battery with wall and vehicle chargers 3 Stars, 0 product ratings 0. State laws vary. moveable jaw to make it easier to 1. I only need this for HFC leaks right now. Whether you need a replacement or an extra charger for your Fieldpiece refrigerant leak detector, the RCA2 will keep you in business when you're on the road. This should fix the issue. Sensitivity better than 0.1 oz/yr Accuracy is wonderful as well as portability makes it a well worth while financial investment. 4.9 average based on 11 product ratings. The ruggedized construction stands up to abuse most other leak detectors can’t handle. 15-hour rechargeable, user replaceable battery. The SRL8 uses a heated diode sensor. We set out to develop the best heated diode leak detector for HVAC/R. LED and Audio alerts. Then, unscrew the snoot on the SRL8 and if replacing gently pull the sensor from the base. (see What’s Included?). We believe the SRL8 is it. As you move. To install or replace the sensor, make sure the unit is turned off. Measuring Instruments Fieldpiece SRL8 Operator's Manual. The SRL8 uses a heated diode sensor. This item, 2 FieldPiece SRL8 Heated Diode Refrigerant Leak Detector , is part of the auction: ONLINE ABSOLUTE & BANKRUPTCY AUCTION: VEHICLES • BOAT • TRACTOR • TOOLS • HVAC EQUIP • NEW SMALL ENGINE PARTS. It detects a CHANGE in concentration, so the wand must keep moving. Info. Share. To install or replace the sen-sor, make sure the unit is turned off. It auto zeros every two seconds until a leak triggers the sensor. It comes in kit form in a rugged, blow-mold case with all of the extras you don’t get from the other guys. Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses or economic loss, or for any claim of such damage, expenses or economic loss. Manual or automatic zeroing. Got a like new Fieldpiece SRL8 from a pawn shop. Installing and Replacing Sensor Replacement sensors (model RHD1) can be ordered for the SRL8. UV dyes can take several hours to travel through a running system and can degrade system components. In-duct problem-solving psychrometer. Fieldpiece pioneered modular expandability, a concept where a single meter uses multiple slide-on accessory head HVAC/R instruments to test most parameters field technicians use everyday. You can also use it while it’s hooked up to the wall or vehicle charger. After that you can manually zero the detector to help further pinpoint leaks.. Up and running in 30 seconds. The heated diode'sadvantage is that it detects. Page 1: Symbols Used The fixed jaw is longer than the 32°F and is usually very convenient. Summary of Contents for Fieldpiece SC76. Fieldpiece SRL8 Manuals & User Guides. If playback doesn't begin shortly, try restarting your device. Find leaks in noisy environments. User Manuals, Guides and Specifications for your Fieldpiece SRL8 Measuring Instruments. These powerhouses can locate refrigerant leaks as small as .03 oz/yr (1g/yr). Select the °F range on the SC76. The filter is at the tip of the snout. select just one wire from a bundle. Ruggedized boot and it fit’s in your hand. I show that the Inficon DTek Stratus is much less sensitive to R410a reference leak than the Fieldpiece SRL8. Measuring Instruments Fieldpiece SRH3 Operator's Manual 2 pages. To install or replace the sensor, make sure the unit is turned off. The MUTE and ZEROing functions allow you to work the way you want to work. ... Summary of Contents for Fieldpiece SRL2. Plus, they’re wireless, tough and have long-lasting sensors, so you can rely on their measurements. second hand to guide the tip along refrigerant. It lasts almost two full workdays on a single charge (if your hunting down leaks all day). Manual or automatic zeroing. The Fieldpiece ergonomic standalone design fits naturally in your hand. Battery life check. vshred.com/Body-type-quiz. Battery: 3.7VDC(nominal), 1800mAh rechargeable lithium ion (model NP-120) replaceable battery. Why to change the sensor on an SRL8 leak detector - YouTube Product failures due to misuse, abuse, normal wear and tear or alterations are not covered by the manufacturers 1-Year Warranty. Fieldpiece SRL8 Leak Detector The SRL8 Heated Diode Refrigerant Leak Detector is designed exclusively to make the HVAC/R Technician’s job easier, faster, safer and more efficient. If playback doesn't begin shortly, try restarting your device. 1. Fieldpiece SRL8 Refrigerant Leak Detector. Page 1 A built in replaceable DO NOT use the SRL2 without the proper fil- filter blocks moisture and harmful particulates. Standalone HVAC/R instruments, detectors and scales give technicians a choice on how they want to work. User Manuals Fieldpiece SRL8 with a strange problem The unit has no scratches and looks brand new so I didn't think I'd have any problems with it. 5.0. Fieldpiece Instruments designs hand-held test instruments exclusively for HVAC/R technicians. Testing Fieldpiece SRL8 leak detector. Two new members of the Fieldpiece family of leak detectors are about to make your job faster and easier than ever before. It is also initially very sensitive. 4. Fieldpiece Repair Department Phone: (714) 634-1844. International Warranty We set out to develop the best heated diode leak detector for HVAC/R. The above limitations or exclusions may not apply to you. If you need to replace a part, this is where you’ll find and order any Fieldpiece parts and accessories. Use the pocket sized PRH2 for incredibly fast and accurate everyday psychrometrics. Testimonial of my Fieldpiece SRL8 Heated Diode Refrigerant Leak Detector. Its major disadvantages are that the sensor becomes less sensitive over life, eventually needing replacement and it is more sensitive to some refrigerants than others. Meets new SAE standards. SRL8 – Heated Diode Refrigerant Leak Detector. Print Material Triggers on all CFCs, HFCs, HCFCs and blends.  More sensitive to some refrigerants than others. Battery life: 15 hours continuous use prior to needing a charge. An error occurred. JJS Technical Services 1900 East Golf Rd., Suite 950 Schaumburg, IL 60173 1-866-4 JJSTECH (1-866-455-7832) sales@jjstech.com Copy link. It then calculates actual superheat in real time using built in P/T charts. Magnetic Hanger. Refrigerant manifold + micron gauge (4 port), Measuring Instruments Fieldpiece SRH3 Operator's Manual, Measuring Instruments Fieldpiece SC660 Operator's Manual, Measuring Instruments Fieldpiece SMAN SM480V Operator's Manual, Measuring Instruments Fieldpiece SC680 Operator's Manual, Measuring Instruments Fieldpiece Job Link SC480 Operator's Manual. Three sensitivity levels from 6.6oz/yr to <0.1oz/yr. Any product manufactured by Fieldpiece Inc. that fails to render service due to defect in workmanship or materials will be replaced or repaired at no charge. Degradation (30%) after 500 charge/discharge cycles or two years, whichever comes first, Low battery LED: Illuminated when approximately 1 hour of battery life remains, Charge time: approximately 4 hours @ 450mA, Operating environment: 32ºF (0°C) to 104ºF (40°C) at <75%RH (non-condensing), Storage environment: <80%RH meter and battery. The SRL8 Heated Diode Refrigerant Leak Detector is designed exclusively to make the HVAC/R Technician's job easier, faster, safer and more efficient. RCA2 - Car Charger for SRL2K7 and SRL8 With all the chargers and plugs you have in your service van, one is bound to get left behind, borrowed indefinitely by a co-worker or lost. The SRL8 was too sensitive on high and went to the lowest setting and found the leak.