When it gets wet, it constricts flow, of air and it will have to be replaced. SRL2 testing an A-coil in an evaporator, 1/4" from the line. here are some quick links to all of our product manuals. Repair price for SRL2 battery is $45. ), 4. Like all of Fieldpiece’s test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician’s job easier, faster, safer and more efficient. ment, it will not trigger on humidity or on oil, and it has nearly the same sensitivity to most, refrigerants.The main disadvantage of infrared, sensors is their sensitivity to mechanical, The heated diode'sadvantage is that it detects, absolute concentration levels so it can be held on, a leak and will continue to beep. The Fieldpiece SRL2K7 is an Infrared Refrigerant Leak Detector for HVACR with superior sensitivity and a rugged design. along with an RMA number. The SRL2 comes in kit form in a rugged, blow-mold case with all of the extras. has a superior combination of sensitivity, speed. The Fieldpiece SRL2K7 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. Low(L), medium(M), or high(H) sensitivity will, The higher the concentration of refrigerant in the, ambient air, the lower the sensitivity setting should, Pressing the MUTE button toggles the sound of, the SRL2 on and off. The SRL2 uses infrared optics to create a, portable refrigerant leak detector technology that. The SRL2 uses an infrared (IR) sensor. ... Superior Sensitivity in a rugged design for HVAC-R Like all of Fieldpiece's test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. Database contains 1 Fieldpiece SRL8 Manuals (available for free online viewing or downloading in PDF): Operator's manual . It detects, must keep moving. You have been successfully registered. Your SRL2 will be repaired or replaced at Fieldpiece's option. Return the tip back to, and past, the spot first, indicated. The user friendly design fits naturally in your hands. The SRL2 comes with wall and car charger for its, ultra-compact Lithium-ion battery which powers the, SRL2 for 8hrs of continuous operation before a, recharge is needed. Add to Cart. The warm-up and calibration, Keep the wand tip moving past suspected leak, Once a leak is detected, sweep the wand back. for SRL2 Catalog: RFE2 (0) In Stock! When in the TURBO mode the first green LED on, SRL2 will strobe, and the audio detection sound will, To exit the TURBO mode, press the PEAK button, again four times in succession, or switch from. FREE Shipping by Amazon. Etc. View and Download Fieldpiece SRL2K7 - Infrared Refrigerant Leak Detector instruction manual online. SRL2K7 - Infrared Refrigerant Leak Detector. in cross section or direction of these lines. We believe the SRL2 is it. It detects a CHANGE in concentration, so the wand must keep moving. That's long enough to last your, Unlike many leak detectors, oil vapor does not, automatic 30 second self-calibration upon power-up, ensures optimal performance. Because the, SRL2 detects change, there is a specific "double-, 1. Fieldpiece's products including but not limited to implied warranties of merchantability and fitness for purpose are limited to the above. Visit our documents page to find all the support you need for your Sena. (Note: If, the SRL2 wand moves through a very high con-, centration of refrigerant, you may need to use in, The SRL2 uses an infrared (IR) sensor. We believe the SRL2 is it. We have emailed you a verification link to to complete your registration. Welcome to ManualMachine. $417.00 inc GST. Buy Now We have emailed you a verification link to to complete your registration. In- Duct Hot Wire Anemometer. 4.6 out of 5 stars 53. Fieldpiece Instruments designs hand-held test instruments exclusively for HVAC/R technicians. This lets the user easily detect leaks in places, that may have refrigerant in the air, such as a refrig-, erator leaking into an enclosed space. 4.8 out of 5 stars 429. It is also initially, very sensitive. We set out to develop the best refrigerant leak detector […] If I miss something here I apologize up front but it is difficult to catch them all! extremely sensitive and will more easily trigger on, abrupt or violent motions as well as very small, Keep the SRL2 away from any areas of potential, refrigerant leakage until the warm-up and calibration, period is over. to turn it off, it will automatically go off in 10 minutes. ... RRE2, 9" Needle Tip Probe for SRL2 Infrared Refrigerant Leak Detector RRE2 RRE2, 9" Needle Tip Probe for SRL2 Infrared Refrigerant Leak Detector. A built in replaceable, filter blocks moisture and harmful particulates. Corona Suppression. SRL2 security sensors pdf manual download. Anonymous on Dec 12, 2016 I found this helpful (0) On startup, meter, The most likely points for refrigerant leaks are at, the soldered joints in refrigerant lines and changes. Heated Diode. Gas is pumped through the tip of the wand into, the sensor within the SRL2 body. The multimeter has a max resistance of 40. and can measure Capacitance, Temperature, Frequency Measurement. The SRL2 uses an infrared (IR) sensor. remain the same over the life of the instrument, the sensor will last the lifetime of the instru. Its disadvantages are that the, sensor becomes less sensitive over life, eventually, needing replacement and it is more sensitive to, fresh air for 4 seconds before moving to step 4, in order to clear the refrigerant within the SRL2. Try the SRL8 for a pin point target. In addition, holding the MUTE, button down for one second will display the remain-. Fieldpiece Expandable Manual Ranging Stick Multimeter for HVAC/R - HS33 Fieldpiece. Fieldpiece - Infrared Leak Detector Like all of Fieldpiece's test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. Set the sensitivity level by pressing the L/M/H but-, ton. which exceeds the toughest SAE J1627 standards. The eight segment LED display indicates the, degree of change in refrigerant concentration. This feature is activated by pressing the, PEAK button four times in succession, and can only. 00 ... Fieldpiece HS33 Expandable Manual Ranging Stick Multimeter for HVAC/R. Product The ABMK3 is best recommended for technicians who purchased the SRL2 Infrared Refrigerant Leak Detector Kit when it originally came with the soft-sided ANC7 case. The SRL2 detects leaks as small as 0.1 oz/year. The SRL2 comes in kit form in a rugged, blow-mold case with all of the extras. If you have question or need technical information about a Fieldpiece tool. Once the SRL2 indicates a change in concentra-, tion, note the spot on the line and keep the tip, moving past the potential leak to refresh the air, space within the SRL2 with clean air. The main advantages of the Fieldpiece IR sensor are that its sensitivity will remain the same over the life of the instrument, the sensor will last the lifetime of the instru ment, it … so does the number of lit bars on the display. Infrared Refrigerant Leak Detector for HVACR - Superior Sensitivity in a Rugged Design for HVACR Like all of Fieldpiece's test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. The main advantages of the Fieldpiece IR sensor are that its sensitivity will remain the same over the life of the instrument, Works on most refrigerants, less on R-22. The source of, the leak will be near the midpoint between the, 5. Manual will be automatically added to "My Manuals", Security Sensors Fieldpiece ACM4 Operator's Manual, Security Sensors Fieldpiece SCM4 Operator's Manual, Security Sensors Fieldpiece SCL2 Operator's Manual. View and Download Fieldpiece SRL8 - Heated Diode Refrigerant Leak Detector instruction manual online. Unscrew the, sensor tip and replace the white filter so that the, rounded end is closest to the tip of the wand. The SRL2 comes in kit form in a rugged, blow-mold case featuring all of the extras. here are some quick links to all of our product manuals. We believe the SRL2 is it. HS36 Manual Fieldpiece - HS36 The HS36 from Fieldpiece, part of the HS36 series of multimeters, features a max current of 0A AC and 0A DC and a max voltage of 600V AC and 0.0006V DC. Return any defective SRL2 to Fieldpiece for war- Instead I’ll provide a brief summary and then we’ll move onto the major Pros and Cons of this unit. It detects a CHANGE in concentration, so the wand must keep moving. We set out to develop the best refrigerant leak detector for HVACR. The main advantages of the, Fieldpiece IR sensor are that its sensitivity will. We set out to develop the best refrigerant leak detector for HVACR. We set out to develop the best refrigerant leak detector for HVACR. The PEAK LED will light when PEAK func-, The TURBO function is an additional 4th sensitiv-, ity that pushes the SRL2 to it highest possible sen-, sitivity. To turn on/off the SRL2 press and hold the, ON/OFF button for one second. Like all of Fieldpiece’s test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician’s job easier, faster, safer and more efficient. If the refrigerant used in the system is in the refrigerant IR spectrum, the detector is going to find it. Quick Shop Fieldpiece Auto & Manual Ranging Stick MultiMeter - HS35. Standalone HVAC/R instruments, detectors and scales give technicians a choice on how they want to work. ... Get it as soon as Wed, Apr 21. If you forget. View and Download Fieldpiece STA2 operator's manual online. You have been successfully registered. As you know there are many different types of refrigerant leak detectors on the market today. AAT3 - Hot-wire Anemometer & Psychrometer Accessory Head, AAV3 - Air Velocity and Temperature Accessory Head, ACM4 - Carbon Monoxide Detector Accessory, ADMN2 - Dual Port Manometer Accessory Head, AOX2 - Oxygen and Carbon Dioxide Accessory Head, ARH4 - Digital Psychrometer Accessory Head, ASX14 - Superheat & Subcooling Accessory Head, ATIR3 - Infrared Temperature Accessory Head, AUA2 - Milliamps & Microamps Accessory Head, AVG2 - Digital Vacuum Micron Gauge Accessory Head, HG3 - Wireless HVAC Guide System Analyzer, JL3KM2 - Job Link® System Dual Port Manometer Probe Kit, JL3LC - Job Link System Wireless Large Pipe Clamp, JL3PC - Job Link® System Premium Pipe Clamp Probe, JL3RH - Job Link® System Flex Psychrometer Probe, SC55 - Dual Display Swivel-Head Clamp Meter, SC76 - Temperature and Capacitance Clamp Meter, SDMN6 - Dual Port Manometer and Pressure Switch Tester, SM380V—Wireless 3-Port SMAN™ Refrigerant Manifold and Micron Gauge, SM480V—Wireless 4-Port SMAN™ Refrigerant Manifold and Micron Gauge, SMAN360 - 3-Port Digital Manifold with Micron Gauge, SMAN460 - Wireless Digital Manifold with Micron Gauge, SPK2 - Folding Pocket In-Duct Thermometer, SPK3 - Rod and IR Temperature Pocket Style Tool, SRL2K7 - Infrared Refrigerant Leak Detector, SRL8 - Heated Diode Refrigerant Leak Detector, SRS1 - Residential, Light Commercial Refrigerant Scale, TC48 - Large Pipe Clamp Type K Thermocouple. Fieldpiece SRL8 Manuals & User Guides. User Manuals, Guides and Specifications for your Fieldpiece SRL8 Measuring Instruments. The SRL2 detects changes in concentration of, refrigerant, not the absolute concentration of refrig-, erant. Turning the PEAK function off will clear the peak, change. Fieldpiece SRL2(K7) Advanced Refrigerant Leak Detector. The Fieldpiece ergonomic standalone design fits naturally in your hand. Manual or automatic zeroing; KIT: Leak Detector with Heated Diode sensor. Repair price for SRL2 meter is $155. HVAC Shop Talk podcast represents the blue collar boys and girls in the skilled trades, especially HVAC. JJS Technical Services 1900 East Golf Rd., Suite 950 Schaumburg, IL 60173 1-866-4 JJSTECH (1-866-455-7832) sales@jjstech.com sensor life, battery life, portability, and ease of use. ing percent of battery charge on the LED bar graph. The Fieldpiece ergonomic standalone design fits naturally in your hand. Insfared Refrigerant Leak Detector. Like all of Fieldpiece's test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. User Manuals If you have question or need technical information about a Fieldpiece tool. Fieldpiece shall not be liable for incidental or consequential dam-ages. The tip of the wand should be fairly close to the, line. Fieldpiece SM480V SMAN Digital Manifold Wireless Data Logging. Welcome to ManualMachine. Review of my Fieldpiece SRL8 Heated Diode Refrigerant Leak Detector. leaks. As an industry leader in all things Bluetooth communication and video recording, we pride ourselves in providing the best product support for all our valued customers. Like all of Fieldpiece's test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. $391.00 $ 391. The SRL2 is more of an area detector and works hand-in-hand with the SRL8. In this case, using a, second hand to guide the tip along refrigerant, 2. Simply put, the SRL2 reacts to all refrigerants the same way. Fieldpiece RFE2 9 inch flex ext. be activated while on the high(H) sensitivity level. Like all of Fieldpiece’s test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician’s job easier, faster, safer and more efficient. Fantastic rechargeable leak detector that works like a charm. SRL2K7 Infrared Refrigerant Leak Detector by Fieldpiece. Keep the tip moving along refrigerant lines at a, 3. The, SRL2 also has a mute button and a peak hold func-, The PEAK function holds the highest change in, concentration achieved while continuing to detect. STA2 measuring instruments pdf manual download. Fieldpiece Auto & Manual Ranging Stick MultiMeter - HS35 Fieldpiece. The sensor, detects changes in concentration, not absolute con-, centration, making it easy to detect leaks even in. When the SRL2 indicates a second, change, note the spot on the line. Fri, May 7 – Fri, May 14 Like all of Fieldpiece’s test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively and Specifically to make the HVACR Technician’s jobs easier, faster, more efficient, and safer. the concentration of refrigerant in the air increases. Brand: Fieldpiece-+ $21.99 each ADD TO CART. The ruggedized construction stands up to abuse most other leak detectors can't handle. This category contains an assortment of miscellaneous parts and replacement parts manufactured by Fieldpiece. This slight delay, protects against inadvertent pressing. The 15-hour battery life lets you work all day and then some before recharging. Model RFL2 contains 10 filters and 5 O-, DO NOT use the SRL2 without the proper fil-, sequence lasts about 30 seconds after ON/OFF is, pressed. Looking for the Sena SRL2 User's Manual? Fieldpiece pioneered modular expandability, a concept where a single meter uses multiple slide-on accessory head HVAC/R instruments to test most parameters field technicians use everyday. Fieldpiece SRL2K7 - SRL2K7, Advanced Infrared Refrigerant Leak Detector Kit - Overview Like all of Fieldpiece's test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. You may need to be within 1/4" (0.63cm) of, a small leak to detect it. $301.08 inc GST. Use, You can order from a distributor extra bags of, replacement parts (model RFL2) are available from, Fieldpiece. The ruggedized construction stands up to … We believe the SRL2 is it. The SRL2 uses an infrared (IR) sensor. high(H) to one of the other sensitivities levels. Allow the SRL2 to fully warm-up before, using to avoid false triggering. We set out to develop the best refrigerant leak detector for HVACR. SKU: RRE2. The filter blocks moisture and other contaminants, from the sensor. © 2021 Fieldpiece Instruments, Inc. All rights reserved. Fieldpiece’s It detects a CHANGE in concentration, so the wand must keep moving. Etc. View and Download Fieldpiece SRL2 operator's manual online. The SRL2 has sensitivity equal to or better than heated element detectors and sensitivity can be adjusted to react like heated elements using the Turbo Mode (see manual) function. Very high concentrations of refrigerant can, cause an overload which can take a few sec-. As. To pinpoint larger leaks adjust sensitivity. Fieldpiece SRL2K7 Infrared Leak Detector Infrared Refrigerant Leak Detector for HVACR – Superior Sensitivity in a Rugged Design for HVACR. Press PEAK to toggle this function on and off. Wall & Car charger. There are a variety of features that come with this unit but I won’t go into each and every one.